Weight Sensors : STS series
- Ideal for managing the remaining amount of bottles, tanks and cylinders with low profile and high accuracy.
- It is impossible to change the design because it has already completed but we can sell this series at reasonable price.
- Line-up with rated weight less than 100 kg, less than 350 mm.
- Cable length 5 m. Fixing hole processing at two places of the lower plate.
Designation System
(A)Rated Capacity
010→100N≒10kgf
(※1N≒0.102kgf)
(B)Outlines
150→150×150×19
A→ | 150 mm |
200 mm |
250 mm |
300 mm |
350 mm |
---|---|---|---|---|---|
Rated Capacity↓ | |||||
100N | 19 | 19 | 19 | 19 | 19 |
300N | 19 | 19 | 25 | 25 | 25 |
500N | 19 | 19 | 28 | 28 | 28 |
1000N | 25 | 25 | 28 | 28 | 28 |
C measurement | 100 | 140 | 190 | 240 | 290 |
D measurement | 128 | 170 | 220 | 270 | 320 |
Mounting pinhole as top plate | φ9 | φ11 | φ11 | φ12 | φ12 |
Mounting pinhole as bottom plate | M5 | M6 | M6 | M8 | M8 |
※Above list of the number described B measurement as thick, C measurement, D measurement, Mounting pinhole as top plate, and mounting pinhole as bottom plate. Please kindly use little hex socket bolt which is smaller than downside fixing bolt, in case of fitting from top side.
Specifications
Rated Capacity | 100,300,500,1000N |
---|---|
Rated Output | 2mv/v±5% |
Nonlinearity | 0.15%R.O. |
Hysteresis | 0.15%R.O. |
Repeatability | 0.2%R.O. |
Allowable overload | 150%R.O. |
Ultimate Overload | 200%R.C. |
Excitation, recommended | 10V AC/DC |
Excitation, maximum | 20V AC/DC |
Zero Balance | ±10%R.O. |
Compensated Temperature Range | 0~50℃ |
Safe Temperature Range | -10~60℃ |
Cable | 5m 4core shield cable (5φ) |
Cable Color | Green:Output+ Black(Blue):Output- Red:Input+ White:Input- Yellow:Shield |
Cover Material | SUS304 |
Electronic balances are highly accurate, lightweight, and suitable for measuring masses with a ratin
TTS series, and LTS series are manufactured to the desired specifications, so tapping holes for fixi
You can tare from the amplifier display. For the MX-11 series, if you press and hold the leftmost ZE
The weight sensor is said to be able to apply a load of 100,000 times. Although it has a very long l
There may be a problem with the load cell of the internal element. If a load exceeding the rated wei
Please refer to the troubleshooting in the specifications or contact our staff. Frequently asked que
Our weight sensor and load cell use a strain gauge for measurement. The resistance foil is attached
Due to its intended use, weight sensors are often used in clean rooms or indoors. The temperature ra
Although it depends on the sensor accuracy, the shape of the sensor sinks up to several mm when a ra
The output of the weight sensor is a weak voltage of several mV / V. Since it is necessary to amplif
The output from our weight sensor and load cell is several mv / v (at rated time). By using it as a