Weight Sensors : LTS series

lts
  • Ultra high precision sensor boasting accuracy of 0.02%
  • It is also possible to process fixing holes at arbitrary positions
  • These can be changed to cable with high chemical resistance (FEP)
  • Mechanical stopper, overload prevention function, can be installed
  • High precision display is possible with the MX – 22 – D 24 series
  • USB connection type compatible! (※ 100mm ~ 1000mm square type only)

Designation System

(A)Rated Capacity
010→100N≒10kgf (※1N≒0.102kgf)

(B)Style
R→Round L→Square

(C)Outlines
150→φ510mm (150□)

A→ 150mm 200mm 250mm 300mm
Rated Capacity↓
50N 37 39 39 39
100N 37 39 39 39
200N 37 43 43 43
300N 37 43 43 43
500N 37 43 43 43

※Above list of the number described B measurement as thick.

Specifications

Rated Capacity 50,100,300,500
Rated Output 2mv/v±10%
Nonlinearity 0.02%R.C.
Hysteresis 0.02%R.C.
Repeatability 0.02%R.C.
Safe Overload 150%R.C.
Ultimate Overload 200%R.C.
Excitation, recommended 10V AC/DC
Excitation, maximum 15V AC/DC
Zero Balance ±2%R.O.
Compensated Temperature Range 0~50℃
Safe Temperature Range -10~50℃
Cable 5m 4core Shield Cable(5φ)
Cable Color Green:Output+
White:Output-
Red:Input+
Black(Blue):Input-
Yellow:Shield
Cover Material SUS304
 
 
 
 
 
 
 
 
 
 
 
 
 

What is the difference between a weight sensor and an electronic balance? 19377 views

Electronic balances are highly accurate, lightweight, and suitable for measuring masses with a ratin

Please tell me how to install the weight sensor. 19311 views

TTS series, and LTS series are manufactured to the desired specifications, so tapping holes for fixi

Is it possible to tare? What should I do? 19283 views

You can tare from the amplifier display. For the MX-11 series, if you press and hold the leftmost ZE

Is there anything I should be careful about when handling and installing? 17545 views

The weight sensor is said to be able to apply a load of 100,000 times. Although it has a very long l

There is something wrong with the zero point. It moves every time it measures. 17530 views

There may be a problem with the load cell of the internal element. If a load exceeding the rated wei

No longer displays the exact weight. 17472 views

Please refer to the troubleshooting in the specifications or contact our staff. Frequently asked que

I want to know the measurement principle of weight sensors and load cells. 15601 views

Our weight sensor and load cell use a strain gauge for measurement. The resistance foil is attached

Is the environment in which it can be installed limited? 15812 views

Due to its intended use, weight sensors are often used in clean rooms or indoors. The temperature ra

Does the shape change when a load is applied? 15800 views

Although it depends on the sensor accuracy, the shape of the sensor sinks up to several mm when a ra

Can it be used only with the weight sensor and load cell? 15788 views

The output of the weight sensor is a weak voltage of several mV / V. Since it is necessary to amplif

What should I get the output from the sensor? 14746 views

The output from our weight sensor and load cell is several mv / v (at rated time). By using it as a