Leakage Sensors : TFP-T series
- Body material: PFA Nut material: ETFE Cable material: FEP
- High chemical resistance product. Reliable use even with chemicals.
- Ultra-thin (10 mm thickness) Since cable comes out from the side, this products can be installed in a narrow space.
- Built-in amplifier(50 mA) , PNP output specification available!
- Interlock function (detachment detection function from fixed holder) standard installed!
- There are 4 kinds of fixing holders and plentifully available!
Designation System
(A)
A→A type(Normal Open)
B→B type(Normal Close)
(B)
NPN→ NPN output
PNP→PNP output
(C)Select holders
OP-1→TH-C OP-3→TH-CR
OP-2→TH-B OP-4→TH-BR
Specifications
Detecting Method | Infrared Photo-reflector |
---|---|
Detecting Output | Transistor Output A type: normal Open B type: Normal Close 50mA MAX |
Detecting Speed | 0.5~1Sec. (Pure Water) |
Power Supply | 12V~24V |
Consumption Current | Under 25mA |
Indicator | LED Turns Green, Detecting LED Turns Red as normal |
Ambient temperature | -10~60℃ |
Weight | Approx.20g(Excluded the Cable) |
Material | PFA |
Cable | 3Core Shield Cable(Material FEP) |
Cable Color | Red:Power Supply Black:Output+ Blue:GND Common |
Summary measure(size) | Sensor diameterφ24 Length 40mm(approx) Height 10.2mm |
Please kindly perform the checking operation when exclusive holder installed.
The standard cable length for the leak sensor is 2M. The cable length can be changed, so please cont
This is an optical sensor that uses an infrared reflective photo reflector. Infrared rays are projec
Yes, you can. There are two types of leak sensor materials: P / P (made of polypropylene) and Teflon
The TFP-T series has a lock type to prevent it from coming off the installation holder. It is a spec
A guideline for selecting a leak sensor. (1) Material made of Teflon → TFP-T series, TFP-F series Ma
The standard holder is delivered with one installed for each leak sensor body, so there is no need t
Yes, we can also manufacture custom products. We will ask you for your desired specifications and ma
Yes, a holder for the leak sensor is required for the following three reasons. (1) To protect the de